beautypg.com

Element manager messages, Table 10 element manager messages – HP StorageWorks 2.32 Edge Switch User Manual

Page 200

background image

Information and error messages

200

Element Manager messages

Table 10

lists Element Manager information and error messages in alphabetical order

Table 10

Element Manager messages

Message

Description

Action

A Preferred Path

already exists between

this Source Port and

this Destination

Domain ID. Please

re-configure the

desired path.

For any source port, only one path

may be defined to each

destination domain ID.

On the Add/Change Preferred Path

dialog box, change the preferred path.

Activating this

configuration will

overwrite the current

configuration.

Confirmation to activate a new

address configuration.

Click Yes to confirm activating the new

address configuration or No to cancel

the operation.

All configuration

names must be unique.

All address configurations must be

saved with unique names.

Save the configuration with a name

that is unique to all saved

configurations.

All FPM ports will be

held inactive while

the director is

configured to 2 Gb/sec

speed. Do you want to

continue?

Occurs when FPM cards are

installed in the director and

director speed is being set to

2 Gb/sec in the Configure Switch

Parameters dialog box.

Replace FPM cards with UPM cards

(UPM cards operate at 1 and 2

Gb/sec) or set the director speed to

1 Gb/sec.

All port names must be

unique.

A duplicate Fibre Channel port

name was configured. All port

names must be unique.

Reconfigure the Fibre Channel port

with a unique name.

All port names must be

unique.

A duplicate port name was

entered. Every configured port

name must be unique.

Reconfigure the port with a unique

name.

An Element Manager

instance is already

open.

Only one instance of the Element

Manager can be open at one

time.

Close the open Element Manager so

the desired instance of the Element

Manager can be opened.

Another Element

Manager is currently

performing a firmware

install.

Only one instance of the Element

Manager can install a firmware

version to the director at a time.

Wait for the firmware installation

process to complete and try the

operation again.

This manual is related to the following products: