background image

Edge Switch Element Manager user guide 203

Cannot install

firmware to a switch

with a failed CTP

card.

Firmware cannot be installed on a

switch with a defective CTP card.

Note that the CTP card is not a FRU. If

the CTP card fails, the switch must be

replaced. After replacement, retry the

firmware install to the switch.

Cannot modify

director/switch speed.

Ports speeds cannot be

configured at a higher

data rate than the

director/switch speed.

Port speeds cannot be configured

at a higher data rate than the

director speed. This message is

displayed when you set director

speed to 1 GB/sec through the

Configure Switch Parameters

dialog box and at least one of the

ports is running at 2 Gb/sec.

Either return the director speed to 2

Gb/sec or configure all port data

speeds to 1 Gb/sec through the

Configure Ports dialog box.

Cannot perform this

operation while the

switch is offline.

This operation cannot take place

while the director or switch is off

line.

Configure the director or switch off line

through the Set Offline State dialog

box and then retry the operation.

Cannot retrieve

current SNMP

configuration.

The director SNMP configuration

cannot be retrieved by the Element

Manager because the Ethernet

link is down or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Cannot retrieve

diagnostics results.

Director diagnostic results cannot

be retrieved by the Element

Manager because the Ethernet

link is down or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Cannot retrieve

information for port.

Port information cannot be

retrieved by the Element Manager

because the Ethernet link is down

or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Cannot retrieve port

configuration.

The port configuration cannot be

retrieved by the Element Manager

because the Ethernet link is down

or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Cannot retrieve port

statistics.

Port statistics cannot be retrieved

by the Element Manager because

the Ethernet link is down or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Cannot retrieve switch

date and time.

The director or switch date and

time cannot be retrieved by the

Element Manager because the

Ethernet link is down or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Table 10

Element Manager messages (continued)

Message