HP StorageWorks 2.32 Edge Switch User Manual
Page 203
![background image](/manuals/397514/203/background.png)
Edge Switch Element Manager user guide 203
Cannot install
firmware to a switch
with a failed CTP
card.
Firmware cannot be installed on a
switch with a defective CTP card.
Note that the CTP card is not a FRU. If
the CTP card fails, the switch must be
replaced. After replacement, retry the
firmware install to the switch.
Cannot modify
director/switch speed.
Ports speeds cannot be
configured at a higher
data rate than the
director/switch speed.
Port speeds cannot be configured
at a higher data rate than the
director speed. This message is
displayed when you set director
speed to 1 GB/sec through the
Configure Switch Parameters
dialog box and at least one of the
ports is running at 2 Gb/sec.
Either return the director speed to 2
Gb/sec or configure all port data
speeds to 1 Gb/sec through the
Configure Ports dialog box.
Cannot perform this
operation while the
switch is offline.
This operation cannot take place
while the director or switch is off
line.
Configure the director or switch off line
through the Set Offline State dialog
box and then retry the operation.
Cannot retrieve
current SNMP
configuration.
The director SNMP configuration
cannot be retrieved by the Element
Manager because the Ethernet
link is down or busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Cannot retrieve
diagnostics results.
Director diagnostic results cannot
be retrieved by the Element
Manager because the Ethernet
link is down or busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Cannot retrieve
information for port.
Port information cannot be
retrieved by the Element Manager
because the Ethernet link is down
or busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Cannot retrieve port
configuration.
The port configuration cannot be
retrieved by the Element Manager
because the Ethernet link is down
or busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Cannot retrieve port
statistics.
Port statistics cannot be retrieved
by the Element Manager because
the Ethernet link is down or busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Cannot retrieve switch
date and time.
The director or switch date and
time cannot be retrieved by the
Element Manager because the
Ethernet link is down or busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Table 10
Element Manager messages (continued)
Message
Description
Action