Information and error messages
202
Cannot enable
beaconing while the
system light is on.
Occurs when choosing Enable
Beaconing option for a failed FRU.
Replace the FRU and enable
beaconing again or enable beaconing
on an operating FRU.
Cannot enable
beaconing while the
system error light is
on.
Beaconing cannot be enabled
while the system error light is on.
Select Clear System Error Light from
Product menu to clear the error light,
then enable beaconing.
Cannot enable Open
Trunking while
Enterprise Fabric Mode
is active and the
switch is offline.
Enterprise Fabric mode is active
and the switch or director is on
line and you attempted to enable
Open Trunking. This message is
displayed only if the optional
Open Trunking feature is installed.
Perform either of the following steps:
Disable Enterprise Fabric Mode option
by selecting the appropriate fabric in
the Fabric Tree portion of the HAFM
Manager window (Fabrics tab) and
then selecting Enterprise Fabric Mode
from the Fabrics menu. When the
Enterprise Fabric Mode dialog box is
displayed, click Start and follow
prompts to disable the feature.
Set the switch or director off line
through the Set Online State dialog
box. Display this dialog box by
selecting Set Online State from the
Element Manager Maintenance menu.
Cannot have E_Ports if
Management Style is
FICON unless
SANtegrity feature is
installed. Please
contact your sales
representative.
Firmware is below the required
level and you attempted to change
management style from Open
Systems to FICON management
style with E_Ports configured, but
SANtegrity Binding is not
installed.
Informational message. If firmware is
below the required level and you
install SANtegrity Binding before
changing to FICON management
style, then E_Ports will remain as
E_Ports when you change to FICON
management style. If SANtegrity
Binding is not installed, setting a
director to FICON management style
will change all E_ports to G_Ports.
Cannot have spaces in
field.
Spaces are not allowed as part of
the entry for this field.
Delete spaces from the field entry.
Cannot install
firmware to a director
with a failed CTP
card.
A firmware version cannot be
installed on a director with a
failed control processor (CTP)
card.
Replace the failed CTP card and retry
the firmware installation.
Table 10
Element Manager messages (continued)
Message
Description
Action