HP StorageWorks 2.32 Edge Switch User Manual
Page 207
Edge Switch Element Manager user guide 207
Could not stop port
diagnostics.
Port diagnostics could not be
stopped by the Element Manager
because the Ethernet link is down
or busy, or because the director is
busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Could not write
firmware to flash.
A firmware version could not be
written from the HAFM appliance
to FLASH memory
Retry the operation again. If the
condition persists, contact the next
level of support.
Control Unit Port
(CUP) name and port
name are identical
(FICON ONLY).
Within the address configuration,
one or more of the port names are
the same as the CUP name.
Make sure all names are unique for
the ports and CUP name.
Date entered is
invalid.
The date is entered incorrectly at
the Configure Date and Time
dialog box. Individual field entries
may be correct, but the overall
date is invalid (for example, a day
entry of 31 for a 30-day month).
Verify that each entry is valid and
consistent.
Device applications
should be terminated
before starting
diagnostics. Press
NEXT
to continue.
Port diagnostics (loopback tests)
cannot be performed on a port
while an attached device
application is running.
Terminate the device application and
perform diagnostics again.
[device WWN] cannot be
removed from the
Switch Membership List
while participating in
Switch Binding. The
device must be
isolated from the
switch, or Switch
Binding deactivated
before it can be
removed.
You attempted to remove a device
WWN from the Switch
Membership List (SANtegrity
Binding feature) while Switch
Binding is enabled.
Remove the device from the switch by
blocking the port, setting the switch off
line, or disabling Switch Binding
through the Switch Binding Change
State dialog box before removing
devices from the Switch Membership
List.
Table 10
Element Manager messages (continued)
Message
Description
Action