1 basic operation – IAI America MSCON User Manual
Page 71

3.1 Basic Operation
63
Ɣ Operation Mode Available
7 types of operation modes are available to select from. The settings are to be established
with Gateway Parameter Setting Tool.
Shown below are the outline.
Operation
Pattern
Contents
Overview
Positioner 1
In Positioner 1 Mode, 256
points of position data can
be registered at the
maximum and is able to stop
at the registered positions.
Monitoring of the current
position is also available.
Simple Direct
Mode
In Simple Direct Mode, the
target position can be
indicated directly by
inputting a value. Monitoring
of the current position is also
available.
Those other than the target
position are to be indicated
in the position table, and the
setting can be done for 256
points at maximum.
Communication with Fieldbus
Dedicated Cable
100V/200V AC
+24V
Target Position
Target Position No.
Control Signal
PLC
Current Position
Completed Position No.
Status Signal
Electric Cylinder
Direct Indication
Mode
Direct Indication 2
Mode
The target position, speed
acceleration/deceleration
and pressing current limit
can be indicated with
inputting a number.
Monitoring of not only the
current position, but also the
current speed and indicated
current are available.
In Direct Indication 2 Mode,
anti-vibration control is
available instead of JOG
operation.
+24V
100V/200V AC
Target Position
Positioning Width
Speed
Acceleration/Deceleration
Push %
Control Signal
PLC
Current Position
Current Value
(Command Value)
Current Speed
(Command Value)
Alarm Code
Status Signal
Communication with Field Network
Dedicated Cable
Electric Cylinder
Position 2 Mode
This is the operation mode
of the position data of 256
points at maximum set in the
position table. The
monitoring of the current
position is not available
This mode is that the
transferred data is reduced
from Positioner 1 Mode.
+24V
100V/200V AC
Target Position No.
Control Signal
PLC
Completed Position No.
Status Signal
Communication with Fieldbus
Dedicated Cable
Electric Cylinder
Position 3 Mode
This is the operation mode
of the position data of 256
points at maximum set in the
position table. The
monitoring of the current
position is not available
This is the mode to control
with the minimized number
of signals to perform the
positioning operation by
reducing the amount of sent
and received data from
Positioner 2 Mode.
+24V
100V/200V AC
Target Position No.
Control Signal
PLC
Completed Position No.
Status Signal
Communication with Fieldbus
Dedicated Cable
Electric Cylinder