3.4 Fieldbus
Type
Address Map
127
Set the parameter No.25 of MSCON
Solenoid valve mode 1
Solenoid valve mode 2
4
5
Category
Port
No.
Symbol
Signal Name
Symbol
Signal Name
0
ST0
Start position 0
ST0
Start position 0
1
ST1
Start position 1
ST1
Start position 1
2
ST2
Start position 2
ST2
Start position 2
3
ST3
Start position 3
–
4
ST4
Start position 4
–
5
ST5
Start position 5
–
6
ST6
Start position 6
–
7
–
–
8
–
Unavailable
–
Unavailable
9
BKRL
Brake release
BKRL
Brake release
10
–
Unavailable
–
Unavailable
11
HOME
Home return
–
12
*STP
Pause
–
13
–
Unavailable
–
Unavailable
14
RES
Reset
RES
Reset
PLC outputψ
MSCON input
15
SON
Servo ON command
SON
Servo ON Command
0
PE0
Position 0 complete
LS0
Retrieval to the Edge
Commands 0
1
PE1
Position 1 complete
LS1
Retrieval to the Edge
Commands 1
2
PE2
Position 2 complete
LS2
Retrieval to the Edge
Commands 2
3
PE3
Position 3 complete
–
4
PE4
Position 4 complete
–
5
PE5
Position 5 complete
–
6
PE6
Position 6 complete
–
Unavailable
7
ZONE1
Zone 1
ZONE1
Zone 1
8
PZONE/
ZONE2
Position zone/
Zone 2
PZONE/
ZONE2
Position zone/
Zone 2
9
–
Unavailable
–
Unavailable
10
HEND
Home return
completion
HEND
Home return
completion
11
PEND
Positioning completion
signal
–
Unavailable
12
SV
Operation preparation
end
SV
Operation preparation
end
13
*EMGS
Emergency stop
*EMGS
Emergency stop
14
*ALM
Alarm
*ALM
Alarm
MSCON output
ψ
PLC input
15
*BALM
Absolute battery
voltage drop alarm
*BALM
Absolute battery
voltage drop alarm
(Note): “*” in codes above shows the signal of the active low.