Pzone – IAI America MSCON User Manual
Page 181

3.8 C
ontrol and functions of Input and output signals of Remote I/O Mode
173
[4] Zone signal and position zone signal (ZONE1, PZONE)
Output
PIO Signal
ZONE1
(Note1)
PZONE
(Note1)
Pattern 0
{
{
Pattern 1
u
{
Pattern 2
u
{
Pattern 4
{
{
Pattern 5
{
{
{
: Available, u: Unavailable
Note1: PZONE Signal can be changed to ZONE1 and ZONE2 Signals by the setting in
Parameter No.149.
1)
Zone output signal
ON
OFF
Zone signal output setting zone
2)
3)
4) 5)
2)
3)
1)
4)
5)
Position 1 input
Start signal
input
(moving start)
Zone signal
turned OFF at
leaving from
setup zone
Zone signal
output at entry
into setup
zone
Moving
comp.
Positioning
completion
signal output
Stop
status
Acceleration
Velocity
Time
Deceleration
This is a function enables to turn a signal on while the actuator is passing a certain position (in
the zone range) or during a stop, in which there are two types.
1) Zone signal (ZONE1) ·······················The output signal is turned ON at the position set by the
proper parameter.
2) Position zone signal (PZONE) ·········The output signal is turned ON at the position set in the
position table.
The feature can play a role as the sensor for judging whether the completion position is good or
not at completion of pressing, setting the continuous operation zone in pitch feed or interlocking
operations of other units in the setting zone.
(1) Zone signal (ZONE)
Set the zone range to the relevant parameter.
1) parameter No. 1 : “Zone Boarder 1 “+” Side”
2) parameter No. 2 : “Zone Boarder 1 “-” Side”
The zone signal ZONE is kept effective also during the emergency stop unless the memory of
the origin is lost due to alarm.