4 fieldbus type address map – IAI America MSCON User Manual
Page 141

3.4 Fieldbus
Type
Address Map
133
7) Writing of Pressing Current Limit
PLC Output (Address n is the input and output top address for MSCON Gateway Unit.)
(Note) If the writing is finished in normal condition, the same content as the demand command
is returned to the response command. If an error is generated, an error response is
returned. [Refer to this Section 16).]
Bit
Address
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
n+2
Demand
Command
[1007h]
0
0
0
1
0
0
0
0
0
0
0
0
0
1
1
1
n+3
Data 0
[Position No.]
㧙
㧙
㧙
㧙
㧙
㧙
㧙
㧙
128
64
32
16
8
4
2
1
n+4
Data 1
[Pressing
Current Limit]
㧙
㧙
㧙
㧙
㧙
㧙
㧙
㧙
128
64
32
16
8
4
2
1
n+5
Data 2
[0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
rit
in
g o
f P
re
ss
in
g C
ur
re
nt
L
im
it
n+6
Data 3
[Axis No.]
㧙
㧙
㧙
㧙
㧙
㧙
㧙
㧙
㧙
㧙
㧙
㧙
㧙
4
2
1
1 word=16 bit
See also other documents in the category IAI America Hardware:
- ERC2 (138 pages)
- ERC2 (188 pages)
- ERC3 (438 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- NS (78 pages)
- ICS(P)A (16 pages)
- RS (46 pages)