Chapter 2 Wiring
43
[6] Regenerative Resistance Circuit
MSCON
[7] Mode Switchover (AUTO/MANU) Circuit
When a switchover of the operation modes (AUTO/MANU) is required with an external input,
connect a device such as a switch between A/M + terminal and A/M – terminal.
If not switching externally, apply a jumper on A/M + terminal and A/M – terminal.
A/M-
A/M+
System I/O Connector
External
Operation Mode
Setting
(AUTO/MANU)
Switch
ON : AUTO
OFF : MANU
Operation Mode Setting
(AUTO/MANU)
Switch
MANU
AUTO
24V
5.6K:
Inner
Circuit
MSCON
RB IN
RB OUT
RB IN
RB OUT
Regenerative Resistor Unit
(RESU-2, RESUD-2)
Regenerative Resistor Unit
(RESU-1,RESUD-1)
CB-SC-REU010
CB-ST-REU010
Caution:
Do not attempt to
connect 5 units or
more of the
regenerative
resistance unit.
(4 units at maximum)
RB
Regenerative
Resistor Unit
Connector
- ERC2 (138 pages)
- ERC2 (188 pages)
- ERC3 (438 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- NS (78 pages)
- ICS(P)A (16 pages)
- RS (46 pages)