beautypg.com

1 parameter list, Chapter 7 parameter – IAI America MSCON User Manual

Page 256

background image

Chapter 7 Parameter

248

7.1 Parameter List

Each axis number has the following parameter table. Have the setting and checking on each

axis number.

The categories in the table below indicate whether parameters should be set or not. There are

five categories as follows:

A : Check the settings before use.

B : Use parameters of this category depending on their uses.

C : Use parameters of this category with the settings at shipments leaving unchanged as a

rule. Normally they may not be set.

D : Parameters of the category are set at shipment in accordance with the specification of

the actuator. Normally they may not be set.

E : Parameters of the category are exclusively used by us for convenience of production.

Changing their settings may not only cause the actuator to operate improperly but also to

be damaged. So, never change the setting of the parameters.

Category do not appear on the teaching tool.

Also, the unused parameter numbers are not mentioned in the list.

No.

C

at

eg

or

y

Name

Symbol Unit

(Note 1)

Input Range

Default factory

setting

Relevant

sections

1 B Zone 1 Positive Side

ZNM1

mm

[deg]

-9999.99 to

9999.99

Actual stroke on

positive side

(Note 2)

7.2 [1]

2 B Zone 1 Negative Side

ZNL1

mm

[deg]

-9999.99 to

9999.99

Actual stroke on

negative side

(Note 2)

7.2 [1]

3 A Soft Limit Positive Side

LIMM

mm

[deg]

-9999.99 to

9999.99

Actual stroke on

positive side

(Note 2)

7.2 [2]

4 A Soft Limit Negative Side

LIML

mm

[deg]

-9999.99 to

9999.99

Actual stroke on

negative side

(Note 2)

7.2 [2]

5 D Home Return Direction

ORG

-

0: Reverse

1: Normal

In accordance

with actuator

(Note 2)

7.2 [3]

6 C Push & Hold Stop Judgment

Period

PSWT

msec

0 to 9999

255

7.2 [4]

7 C Servo Gain Number

PLGO

-

0 to 31

In accordance

with actuator

(Note 2)

7.2 [5]

7.3

8 B Default Velocity

VCMD

mm/s

[deg/s]

1 to Actuator’s

max. speed

Rated actuator

speed

(Note 2)

7.2 [6]

9 B Default

Acceleration/Deceleration

ACMD

G

0.01 to actuator's

max. acceleration/

deceleration

Rated actuator's

acceleration/

Deceleration

(Note 2)

7.2 [7]

10 B Default Positioning Width

INP

mm

[deg]

0.01 to 999.99

0.10

7.2 [8]

13 C Current-Limiting Value During

Home Return

ODPW

%

1 to 300

In accordance

with actuator

(Note 2)

7.2 [9]

14 E Dynamic Brake

FSTP

-

0: Disabled

1: Enabled

1

7.2 [10]

15 B Pause Input Disable

Selection

FPIO

-

0: Enabled

1: Disabled

0

7.2 [11]

18 E Home Position Check Sensor

Input Polarity

AIOF

-

0 to 2

In accordance

with actuator

(Note 2)

7.2 [12]

19 E Overrun Sensor Input Polarity

AIOF

-

0 to 2

In accordance

with actuator

(Note 2)

7.2 [13]

20 E Creep Sensor Input Polarity

AIOF

-

0 to 2

In accordance

with actuator

(Note 2)

7.2 [14]

21 B Servo ON Input Disable

Selection

FPIO

-

0: Enabled

1: Disabled

0

7.2 [15]

Note 1: The unit [deg] is for rotary actuator. It is displayed in mm in the teaching tools.

Note 2: The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.