4 fieldbus type address map – IAI America MSCON User Manual
Page 120

3.4 Fieldbus
Type
Address Map
112
PLC Output (m is PLC output top word address for each axis number)
Address m
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Target
Position
(Lower word)
Address m+1
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Target
Position
(Upper word)
(Note)If the target position is a negative value, the input is made with two’s implement.
䎃
䎃
Address m+2
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Positioning
Width
(Lower word)
32,768
16,384
8,192
4,096
2,048
1,024
512
256
128
64
32
16
8
4
2
1
䎃
䎃
Address m+3
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Positioning
Width
(Upper word)
–
–
–
–
–
–
–
–
–
–
–
–
524,288
262,144
131,072
65,536
䎃
䎃
Address m+4
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Velocity
32,768
16,384
8,192
4,096
2,048
1,024
512
256
128
64
32
16
8
4
2
1
䎃
䎃
Address m+5
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Acceleration/
Deceleration
–
–
–
–
–
–
–
256
128
64
32
16
8
4
2
1
䎃
䎃
Address m+6
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Current
limitation value
while pressing
–
–
–
–
–
–
–
–
128
64
32
16
8
4
2
1
䎃
䎃
Address m+7
b15 b14 b13 b12 b11 B10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Control
Signal
B
K
R
L
INC
DIR
P
U
S
H
GSL1
GSL0
N
TC
1
N
TC
0
M
O
D
1
M
O
D
0
–
SON
R
E
S
S
TP
HOME
CSTR
䎃
1 word=16 bit