4 fieldbus type address map – IAI America MSCON User Manual
Page 121

3.4 Fieldbus
Type
Address Map
113
PLC Input (m is PLC input top word address for each axis number).
䎃
䎃
Address m
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Current
Position
(Lower word)
Address m+1
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Current
Position
(Upper word)
(Note) If the target position is a negative value, the output is made with two’s implement.
Address m+2
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Command
Current
(Lower word)
32,768
16,384
8,192
4,096
2,048
1,024
512
256
128
64
32
16
8
4
2
1
Address m+3
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Command
Current
(Upper word)
–
–
–
–
–
–
–
–
–
–
–
–
524,288
262,144
131,072
65,536
Address m+4
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Current Speed
(Note)It will be expressed with two’s implement for a negative value.
Address m+5
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Unavailable
Address m+6
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Alarm Code
Address m+7
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Status Signal
E
M
G
S
CRDY
ZO
N
E
2
ZO
N
E
1
–
–
–
MEND
B
A
LM
–
P
S
FL
S
V
A
LM
M
O
V
E
HEND
P
E
N
D
1 Word㧩16 bit