beautypg.com

3 wiring method – IAI America MSCON User Manual

Page 55

background image

Chapter 2 Wiring

47

2.3 Wiring Method

2.3.1 Wiring of Control Power Supply and Drive Power Supply Input Connector

Insert the wires to the enclosed connector (plug).

Strip the sheath of the applicable wires for 7mm and insert them to the connector. When

inserting, twist the affixing screw on the side of the inlets to the left with a slotted screw driver to

open an inlet. After inserting a cable, twist the affixing screw to the right to hold the cable.

(1) Control Power Supply Input Connector

Power Supply Input

Connector

Model

Remarks

Cable Side

MC1.5/5-STF-3.81

Enclosed in standard

package

Manufactured by PHOENIX

CONTACT

Controller Side

MC1.5/5-GF-3.81

Pin

No.

Signal

Name

Contents

Applicable Cable

1

BK PWR+

2

BK PWR-

Brake Power Input

(24V DC ±10%)

KIV0.75mm

2

(AWG19)

3

24V

4

0V

Control Power Input

(24V DC ±10%)

KIV3.5 to 0.75mm

2

(AWG 12 to 19)

Select the cable thickness allowable

for the current figured out in the power

capacity.

If supplying power with using a 24V

DC, having it turned ON/OFF, keep the

0V connected and have the +24V

supplied/cut (cut one side only).

5

FG

Functional Ground

Cable

It is connected to the shield of the

encoder connector and fieldbus frame

ground terminal inside the unit.

Front view of

connector on

controller side

Accessory

Connector

(Plug)

BK

PWR

+

-

24V

0V

FG