3 wiring method – IAI America MSCON User Manual
Page 55

Chapter 2 Wiring
47
2.3 Wiring Method
2.3.1 Wiring of Control Power Supply and Drive Power Supply Input Connector
Insert the wires to the enclosed connector (plug).
Strip the sheath of the applicable wires for 7mm and insert them to the connector. When
inserting, twist the affixing screw on the side of the inlets to the left with a slotted screw driver to
open an inlet. After inserting a cable, twist the affixing screw to the right to hold the cable.
(1) Control Power Supply Input Connector
㩷
㩷
㩷
Power Supply Input
Connector
Model
Remarks
Cable Side
MC1.5/5-STF-3.81
Enclosed in standard
package
Manufactured by PHOENIX
CONTACT
Controller Side
MC1.5/5-GF-3.81
Pin
No.
Signal
Name
Contents
Applicable Cable
1
BK PWR+
2
BK PWR-
Brake Power Input
(24V DC ±10%)
KIV0.75mm
2
(AWG19)
3
24V
4
0V
Control Power Input
(24V DC ±10%)
KIV3.5 to 0.75mm
2
(AWG 12 to 19)
Select the cable thickness allowable
for the current figured out in the power
capacity.
If supplying power with using a 24V
DC, having it turned ON/OFF, keep the
0V connected and have the +24V
supplied/cut (cut one side only).
5
FG
Functional Ground
Cable
It is connected to the shield of the
encoder connector and fieldbus frame
ground terminal inside the unit.
Front view of
connector on
controller side
Accessory
Connector
(Plug)
BK
PWR
+
-
24V
0V
FG