7 sflow rate, Sflow rate – PLANET WGSW-50040 User Manual
Page 409

no sflow counter-interval
Function:
Configure the max interval of the sFlow statistic sampling; the “no” form of this command deletes
the statistic sampling interval value.
Parameter:
Command Mode:
Port Mode
Default:
No default value
Usage Guide:
If no statistic sampling interval is configured, there will not be any statistic sampling on the interface.
Example:
Set the statistic sampling interval on the interface e1/1 to 20 seconds.
Switch(Config-If-Ethernet1/1)#sflow counter-interval 20
30.7 sflow rate
Command:
sflow rate { input
no sflow rate [input | output]
Function:
Configure the sample rate of the sFlow hardware sampling. The “no” form of this command deletes
the sampling rate value.
Parameter:
Command Mode:
Port Mode.
Default:
No default value.
Usage Guide:
The traffic sampling will not be performed if the sampling rate is not configured on the port. And if
the ingress group sampling rate is set to 10000, this indicates there will be one group be sampled
every 10000 ingress groups.