2 sflow agent-address, Sflow agent, Address – PLANET WGSW-50040 User Manual
Page 406

Default:
The destination port of the sFlow packet is defaulted at 6343, and the analyzer has no default
address.
Usage Guide:
If the analyzer address is configured at Port Mode, this IP address and port configured at Port Mode
will be applied when sending the sample packet. Or else the address and port configured at global
mode will be applied. The analyzer address should be configured to let the sFlow sample proxy
work properly.
Example:
Configure the analyzer address and port at global mode.
switch (config)#sflow destination 192.168.1.200 1025
30.2 sflow agent-address
Command:
sflow agent-address <agent-address>
no sflow agent-address
Function:
Configure the sFlow sample proxy address. The “no” form of this command deletes the proxy
address.
Parameter:
Command Mode:
Global Mode.
Default:
None default value.
Usage Guide:
The proxy address is used to mark the sample proxy which is similar to OSPF or the Router ID in
the BGP. However it is not necessary to make the sFlow sample proxy work properly.
Example:
Sample the proxy address at global mode.
switch (config)#sflow agent-address 192.168.1.200