12. Configuring EC9535
Setting Up EC9535 Communication
3 Connect the other end of the cable to the PC running the UniConfig application using a DE9
connector.
4 When done configuring, remove the temporary connection.
EC9535 Frame Diagnostic Connections
There are two diagnostic ports located on the rear of the EC9535, labeled ‘DIAG’. The diagnostic
ports are fixed at a baud rate of 38400, RS-232.
How to Make Frame Diagnostic Connections
1 Locate the diagnostic connections on the rear of the EC9535. The diagnostic connections are
labeled ‘DIAG’:
Figure 12-1. EC9535 Diagnostic Connections (Rear View)
2 Connect to the ‘DIAG’ connection in the ‘PRI’ section using a DE9 connector and a serial
cable. The ports are set for RS-232:
The following lists the DE9 pin connectors for RS-232:
3 Connect the other end of the cable to the PC running the UniConfig application.
4 If a secondary (optional for redundancy) control card is installed, connect to the ‘DIAG’ con-
nection in the ‘SEC’ section using a DE9 connector and a serial cable as described in step 2 and
step 3.
SEC
CTRL
LOOP
THRU
10/100 BT
10 B 2
PRI
CTRL
10 B 2
10/100 BT
AES
REF 1
AES
REF 2
DIAG
DIAG
CTRL 1
CTRL 2
CTRL 1
CTRL 2
Diagnostic Connections
PC End (DCE)
Pins
Router End (DTE)
DCD
1
Ground
RXD
2
TXD
TXD
3
RXD
DTR
4
DSR
Signal Ground
5
Signal Ground
DSR
6
DTR
RTS
7
CTS
CTS
8
RTS
Ground
9
Ground