12. Configuring EC9535

Setting Up EC9535 Communication

3 Connect the other end of the cable to the PC running the UniConfig application using a DE9

connector.

4 When done configuring, remove the temporary connection.

EC9535 Frame Diagnostic Connections

There are two diagnostic ports located on the rear of the EC9535, labeled ‘DIAG’. The diagnostic
ports are fixed at a baud rate of 38400, RS-232.

How to Make Frame Diagnostic Connections

1 Locate the diagnostic connections on the rear of the EC9535. The diagnostic connections are

labeled ‘DIAG’:

Figure 12-1. EC9535 Diagnostic Connections (Rear View)

2 Connect to the ‘DIAG’ connection in the ‘PRI’ section using a DE9 connector and a serial

cable. The ports are set for RS-232:

The following lists the DE9 pin connectors for RS-232:

3 Connect the other end of the cable to the PC running the UniConfig application.

4 If a secondary (optional for redundancy) control card is installed, connect to the ‘DIAG’ con-

nection in the ‘SEC’ section using a DE9 connector and a serial cable as described in step 2 and
step 3.

SEC

CTRL

LOOP

THRU

10/100 BT

10 B 2

PRI

CTRL

10 B 2

10/100 BT

AES

REF 1

AES

REF 2

DIAG

DIAG

CTRL 1

CTRL 2

CTRL 1

CTRL 2

Diagnostic Connections

PC End (DCE)

Pins

Router End (DTE)

DCD

1

Ground

RXD

2

TXD

TXD

3

RXD

DTR

4

DSR

Signal Ground

5

Signal Ground

DSR

6

DTR

RTS

7

CTS

CTS

8

RTS

Ground

9

Ground