11. Managing Machine Control Ports
Updating Machine Control Port Switching
To update a single machine control switching configuration, that is, changing what one port sends
to another port, enter the new port to port that you want to configure and perform a single ‘take’.
Unique to machine control signals, any given port may only connect to itself (tri-stated) or to one
other bidirectional port. Because of this, port connections are exclusive, requiring prior connec-
tions, if they exist, to first be broken before a new connection can be established. Only single ports
can be reconfigured, not a range of ports..
How to Update Switching Configurations
1 Launch UniConfig. (See
2 Select a control card. (See
3 From the menu bar, select ‘Window > Connections’. The ‘Connections’ window appears, as
shown in Figure 11-2.
4 Select the ‘Machine Control’ tab to bring it to the front, as shown in Figure 11-5.
5 In the ‘Physical Output Range’ section, enter a ‘Start’ and ‘End’ number in the fields provided
and click
Read Outputs
. The corresponding ports display on the tab.
If the ‘Machine Control’ tab is blank, perform a ‘Diagonal Take’, connecting port 1 to port 1,
and so on. When ports are connected to themselves in this manner, the port’s connections are
automatically tri-stated. (See
Testing Machine Control Ports Switching
6 To perform a single ‘take’ of a single input to a single output, perform the following:
Enter the new ‘Input’ and ‘Output’ in the fields provided in the ‘Single Take’ section. For
example, if currently input 1 switches to output 3, and you want input 1 to switch to output 6,
enter 6 in the ‘Output’ field.
Click
Execute
. A ‘take’ is performed based on the ‘take’ format selected. (See
7 (Optionally) create a switching configuration “salvo”. For more information, see
8 Repeat steps 2–6 for each control card being updated.
Note
A port must be in ‘Dynamic’ mode in the ‘Machine Control Setup’ window in
order to make changes in the ‘Connections’ window. (See
Note
Each control card must be configured separately.
Note
When the Machine Control tab is selected, entries in ‘Physical Output Range’
and in ‘Single Take’ fields refer to machine control port numbers, not physical
input or output numbers on the frame.
Note
A port must be in ‘Dynamic’ mode in the ‘Machine Control Setup’ window in
order to make changes in the ‘Connections’ window. (See