How to test machine control signals, 4 select the ‘machine control’ tab, Managing machine control ports – Grass Valley UniConfi NVISION Series v.1.3 User Manual
Page 121

UniConfig Configuration Application • User’s Guide
109
11. Managing Machine Control Ports
Testing Machine Control Ports Switching
How to Test Machine Control Signals
1 Launch UniConfig. (See
2 Select a control card. (See
3 From the menu bar, select ‘Window > Connections’. The ‘Connections’ window appears with
blank fields.
4 Select the ‘Machine Control’ tab:
Figure 11-5. Example of Connections Window with Machine Control Tab in Front
Each input is listed with its corresponding output.
5 In the ‘Physical Output Range’ section, enter a ‘Start’ and ‘End’ number in the fields provided
and click
Read Outputs
. The corresponding ports display on the tab.
If the ‘Machine Control’ tab is blank, perform a ‘Diagonal Take’ (step 7), connecting port 1 to
port 1, and so on. When ports are connected to themselves in this manner, the port’s connec-
tions are automatically tri-stated.
Note
Each control card must be configured separately.
Note
When the ‘Machine Control’ tab is selected, entries in the ‘Physical Output
Range’ and in ‘Single Take’ fields refer to machine control port numbers, not
physical input or output numbers on the frame.