Id - immediate distance, Command details, Examples – Applied Motion RS-232 User Manual
Page 98

98
920-0002 Rev. I
2/2013
Host Command Reference
ID - Immediate Distance
Compatibility: All drives
BLu, STAC6
Requests the total relative distance moved in the last completed move.
SV, ST-Q/Si, ST-S, STM
Requests the immediate relative distance traveled from the beginning of the last move. Once the move is finished
the value will be equal to the relative distance of that last move until another move is initiated, at which time the
value will zero and begin tracking the new relative distance moved.
Command Details:
Structure
ID
Type
IMMEDIATE
Usage
READ ONLY
Non-Volatile
NO
Register Access
“d” (052)
Units
encoder counts (servo)
steps (stepper)
Examples:
Command
Drive sends
Notes
ID
ID=00002710
10000 (10000 counts into CW move)
ID
ID=FFFFD8F0
-10000 (10000 counts into CCW move)
If the IF command is set with Parameter #1=D
ID
ID=10000
10000 counts into CW move
ID
ID=-10000
10000 counts into CCW move