Pt - pulse type, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 161: Examples

161
920-0002 Rev. I
2/2013
Host Command Reference
PT - Pulse Type
Compatibility: All drives
See also:
CM, EG commands
Sets or requests the type of incoming pulse used in CM7 (Pulse and Direction mode).
The possible input signals are as follows:
0 = Step / Direction
1 = CW / CCW Pulse
2 = AB Quadrature (master encoder)
4 = Step / ~Direction (direction input is reversed from PT0)
6 = BA Quadrature (count direction is reverse of PT2)
Command Details:
Structure
PT{Parameter #1}
Type
BUFFERED
Usage
READ / WRITE
Non-Volatile
YES
Register Access
None
Parameter Details:
Parameter #1
Pulse Type
- units
integer
- range
0, 1, 2, 4, or 6
Examples:
Command
Drive sends
Notes
PT0
-
Instruct the drive to follow step/direction pulses from a master controller.
PT PT=0
PT2
-
Instruct the drive to follow AB quadrature encoder pulses, typically from a
master encoder.
PT PT=2