R| - register or, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 193: Examples

193
920-0002 Rev. I
2/2013
Host Command Reference
R| - Register OR
Compatibility: Q drives only
Affects:
All data registers
See also:
R+, R-, R*, R/, R&, RD, RI, QJ commands
Do a “bit-wise” OR of the contents of the first data register with the contents of the second data register and place
the result in the accumulator data register, User-Defined register “0”. This is a 32-bit operation.
All math operations affect the “condition code” used by the QJ (Queue Jump) command. Can set condition codes
T, F, N, P, and Z.
Command Details:
Structure
RI(Parameter #1)(Parameter #2)
Type
BUFFERED
Usage
WRITE ONLY
Non-Volatile
NO
Register Access
“0” (000), Accumulator
Parameter Details:
Parameter #1
First data register
- units
data register assignment
- range
All data registers
Parameter #2
Second data register
- units
data register assignment
- range
All data registers
Examples:
Command
Drive sends
Notes
R|i1
-
OR the contents of inputs register “i” with user-defined register “1”
and place the results in accumulator register “0”