Il - immediate low output, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 102: Examples

102
920-0002 Rev. I
2/2013
Host Command Reference
IL - Immediate Low Output
Compatibility: All drives
See also:
IH, SO commands.
Sets an output low (closed) immediately. Use SO instead if you don’t want the output to change until a buffered
command (like a move) is complete.
Command Details:
Structure
IL(Parameter #1)
Type
IMMEDIATE
Usage
WRITE ONLY
Non-Volatile
NO
Register Access
None
Parameter Details:
(See Appendix F: Working With Inputs and Outputs)
Examples:
Command
Drive sends
Notes
IL1
-
Output 1 goes low immediately
IL2
-
Output 2 goes low immediately
To force Outputs on main driver board when using an SE, QE, or Si drive
ILY1
-
Output 1 of main driver board goes low immediately
ILY2
-
Output 2 of main driver board goes low immediately
This manual is related to the following products: