Host Command Reference
ZR - Regen Resistor Value
Compatibility: BLuAC5 and STAC6 drives only
Sets or requests the regeneration resistor value. BLuAC and STAC drives dynamically calculate the continuous
wattage induced into an external regeneration resistor and must know the value of the regen resistor to do this
effectively.
Command Details:
Structure
ZR{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
Yes
Register Access
None
Parameter Details:
Parameter #1
Value of regen resistor
- units
Ohms
- range
25 - 100
Examples:
Command
Drive sends
Notes
ZR50
-
50 ohm external regen resistor connected to drive