Cg - anti-resonance filter gain, Command structure, Command details – Applied Motion RS-232 User Manual
Page 50: Parameter details, Examples

50
920-0002 Rev. I
2/2013
Host Command Reference
CG - Anti-resonance Filter Gain
Compatibility: Stepper drives only
Affects:
Mid-range performance of step motors
See also:
CF command
Sets or requests the anti-resonance filter gain setting. This setting is unit-less and works in conjunction with the
anti-resonance filter frequency setting (CF) to cancel instabilities due to mid-band resonance.
NOTE: We strongly suggest using the appropriate Configurator software application to set this value by entering
as accurate a load inertia value as possible in the motor settings window.
Command Structure:
CG{Parameter #1}
Command Details:
Structure
CG{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
None
Parameter Details:
Parameter #1
Filter gain
- units
integer number
- range
0 - 32767
Examples:
Command
Drive sends
Notes
CG800
-
Set anti-resonance filter gain to 800
CG CG=800