Examples – Applied Motion RS-232 User Manual
Page 46

46
920-0002 Rev. I
2/2013
Host Command Reference
*Current setting in stepper drives depends on the selected motor. Use Configurator software to select a motor
and set the maximum current setting.
Examples:
BLu, SV, SVAC3
Command
Drive sends
Notes
CC4.50
-
Set continuous current to 4.5 amps rms
CC CC=4.5
STAC6
Command
Drive sends
Notes
CC4.50
-
Set running current to 4.5 amps
CI2
-
Set idle current to 2.0 amps
CC1.8
-
Set idle current to 1.8 amps
CC CC=1.8
CI
CI=1.8
CI automatically set to 1.8 amps along with CC1.8 command
ST-Q/Si, ST-S, STM, STAC5
Command
Drive sends
Notes
CC3
-
Set running current to 3.0 amps
CI
CI=1.5
CI automatically set to 1.5 amps along with CC3 command
CI1
-
Set idle current to 1.0 amps
This manual is related to the following products: