Hp - 4th harmonic filter phase, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 92: Examples

92
920-0002 Rev. I
2/2013
Host Command Reference
HP - 4th Harmonic Filter Phase
Compatibility: Stepper drives only
Affects:
Low-speed performance of step motors
See also:
HG command
Sets or requests the 4th harmonic filter phase setting. This setting works in conjunction with the 4th harmonic
filter gain setting (HG) to reduce low-speed torque ripple in step motors.
NOTE: We strongly suggest you set this value in the ST Configurator software application only.
Command Details:
Structure
HP{Parameter #1}
Type
IMMEDIATE
Usage
READ/WRITE
Non-Volatile
YES only when set in Configurator software, otherwise NO
Register Access
None
Parameter Details:
Parameter #1
Filter phase
- units
integer number
- range
-125 to +125
Examples:
Command
Drive sends
Notes
HG105
-
Set 4th harmonic filter gain to 105
HG HG=105