Host Command Reference
J
Jog Velocity (JS)
026
Short
0.25 rpm
All drives
The “J” register units are 0.25 rpm, which means that the value of the “J” register is equal to 240 times the
JS command value. In other words, to achieve a jog speed value of 7 rev/sec send the command RLJ1680.
K
RESERVED
027
-
-
-
L
RESERVED
028
-
-
-
M
Max Velocity (VM, servo)
Accel/Decel Current (CA,
STM Integrated Stepper)
029
Short
Servo: 0.01 amps RMS
Stepper: 0.01 amps, peak-of-
sine
Servo drives and STM
Integrated Steppers
N
Continuous Current (CC,
servo)
Running Current (CC,
stepper)
030
Short
Servo: 0.01 amps RMS
Stepper: 0.01 amps, peak-of-
sine
All drives
O
Peak Current (CP, servo)
Idle Current (CI, stepper)
031
Short
Servo: 0.01 Amps RMS
Stepper: 0.01 amps, peak-of-
sine
All drives
P
Absolute Position Command
032
Long
counts
All drives
Q
RESERVED
033
-
-
-
R
Steps per Rev*
034
Short
counts
All drives
* Note: R = EG for servo drives. R = EG/2 for stepper drives.
S
Pulse Counter
035
Long
counts
All drives
The “S” register counts pulses coming into the STEP/X1 and DIR/X2 inputs of the drive. This is particularly
useful when in Command Mode 7 (see CM command) or executing an FE (Follow Encoder) command. To
zero the “S” register send the command RLS0.
T
Total Count
036
Long
(see below)
Q drives only
The “T” register is automatically saved at power down and restored at power up.
U
Change Velocity (VC)
037
Short
0.25 rpm
All drives
The “U” register units are 0.25 rpm, which means that the value of the “U” register is equal to 240 times the
VC command value. In other words, to achieve a change velocity value of 7 rev/sec send the command
RLU1680.
V
Velocity (VE)
038
Short
0.25 rpm
All drives
The “V” register units are 0.25 rpm, which means that the value of the “V” register is equal to 240 times the
VE command value. In other words, to achieve a velocity value of 7 rev/sec send the command RLV1680.
W
Time Stamp
039
Short
0.001 sec
Q drives only