Av - analog offset value, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 35: Examples

35
920-0002 Rev. I
2/2013
Host Command Reference
AV - Analog Offset Value
Compatibility: All drives
Affects:
All Analog input functions
See also:
AF, AP, AZ, CM & Feed commands
Sets or requests the analog offset value in volts.
Command Details:
Structure
AV{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
“Z” (042)
Note: Units of AV command are different than units of “Z”
register; see Data Registers section for more details
Parameter Details:
Parameter #1
Analog offset value
- units
Volts
- range
BLu, SV, STAC6, ST-Q/Si, STAC5, SVAC3: -10.000 to
10.000
ST-S, STM: -5.000 to 5.000
Examples:
Command
Drive sends
Notes
AV0.25
-
Set analog offset to 0.25 Volts
AV AV=0.25
This manual is related to the following products: