Sj - stop jogging, Command details, Examples – Applied Motion RS-232 User Manual
Page 201

201
920-0002 Rev. I
2/2013
Host Command Reference
SJ - Stop Jogging
Compatibility: All drives
Affects:
CJ command
See Also:
JA, CJ, ST, SK, SM commands
Stops the motor when jogging (CJ starts jogging). Jog decel rate is defined by the JA command.
Command Details:
Structure
SJ
Type
IMMEDIATE
Usage
WRITE ONLY
Non-Volatile
NO
Register Access
None
Examples:
Command
Drive sends
Notes
SJ
-
Stops jogging immediately using the deceleration rate set by the JA
command