Ag - analog velocity gain, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 23: Examples

23
920-0002 Rev. I
2/2013
Host Command Reference
AG - Analog Velocity Gain
Compatibility: All stepper drives and SV servo drives
Affects:
Analog velocity modes
See also:
CM command
Sets or requests the gain value used in analog velocity / oscillator modes. The gain value is used to establish the
relationship between the analog input and the motor speed. The units are 0.25 rpm. For example, if the analog
input is scaled to 0 - 5 volt input and the gain is set to 2400, when 5 volts is read at the analog input the motor will
spin at 10 rps. TIP: To set the analog velocity gain to the desired value, multiply the desired motor speed in rps by
240, or the desired motor speed in rpm by 4.
Command Details:
Structure
AG{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
None
Parameter Details:
Parameter #1
Analog velocity gain value
- units
0.25 rpm
- range
-32767 to 32767
Examples:
Command
Drive sends
Notes
AG3000
-
Set top speed of analog velocity mode to 12.5 rps
AG AG=3000