Cf - anti-resonance filter frequency, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 49: Examples

49
920-0002 Rev. I
2/2013
Host Command Reference
CF - Anti-resonance Filter Frequency
Compatibility: Stepper drives only
Affects:
Mid-range performance of step motors
See also:
CG command
Sets or requests the anti-resonance filter frequency setting. This setting is in Hz and works in conjunction with the
anti-resonance filter gain setting (CG) to cancel instabilities due to mid-band resonance.
NOTE: We strongly suggest using the appropriate Configurator software application to set this value by entering
as accurate a load inertia value as possible in the motor settings window.
Command Details:
Structure
CF{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
None
Parameter Details:
Parameter #1
Filter frequency
- units
Hz
- range
1 - 2000
Examples:
Command
Drive sends
Notes
CF1400
-
Set anti-resonance filter frequency to 1400 Hz
CF CF=1400