PP - Power-up Peak current
Compatibility: Servo drives only
Affects:
Motor current, especially during acceleration and deceleration
See also:
CC, CP, PC commands
Sets or requests the power-up peak (RMS) current setting of the servo drive. This command differs from the CP
command in that in addition to setting the peak current of the drive, PP also immediately saves the setting to NV
memory. In other words, PP = CP + SA.
Command Details:
Structure
PP{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
None
Parameter Details:
Parameter #1
Power-up peak current limit
- units
amps RMS (resolution is 0.01 amps)
- range
BLuDC4: 0 - 13.5
BLuDC9: 0 - 18.0
BLuAC5: 0 - 15.0
SV7: 0 - 7.0
SVAC3 (120V): 0 - 7.5
SVAC3 (220V): 0 - 3.75
Examples:
Command
Drive sends
Notes
PP6
-
Set power-up peak current to 6.0 amps RMS
PP PP=6