Host Command Reference
IQ - Immediate Current (Actual)
Compatibility: Servo drives only
Requests present actual current. This current reading is the actual current measured by the drive. As with the
Commanded Current this is an RMS value that represents the DC current in the motor windings.
Command Details:
Structure
IQ
Type
IMMEDIATE
Usage
READ ONLY
Non-Volatile
NO
Register Access
None
Units
0.01 Amps
Examples:
Command
Drive sends
Notes
IQ
IQ=015E
3.5 Amps
IQ
IQ=FEA2
-3.5 Amps
If the IF command is set with Parameter #1=D
IQ
IQ=350
3.5 Amps
IQ
IQ=-350
-3.5 Amps