27
920-0002 Rev. I
2/2013
Host Command Reference
AL - Alarm Code
Compatibility: All drives
See also:
AI, AR, AX commands, Appendix
Reads back an equivalent hexadecimal value of the Alarm Code’s 16-bit binary word.
Command Details:
Structure
AL
Command Type
IMMEDIATE
Usage
READ ONLY
Non-Volatile
NO
Register Access
“f” (054)
Note: response to AL command is a different format than
the response to the RLf command. See Appendix F for
details.
Units
Hexadecimal value of 16-bit binary word (see below)
Response Details:
Hex Value
BLu
SV
STAC6
ST
STM
0001
Position Limit
0002
CCW Limit
0004
CW Limit
0008
Over Temp
0010
Excess Regen*
Internal Voltage
Excess Regen
Internal Voltage
Internal Voltage
0020
Over Voltage
0040
Under Voltage*
Under Voltage
Under Voltage
Under Voltage
Under Voltage
0080
Over Current
0100
Bad Hall Sensor
Open Motor Winding
0200
Bad Encoder
(not used)
0400
Comm Error
0800
Bad Flash
1000
Wizard Failed
No Move
2000
Current Foldback
Motor Resistance
Out of Range
(not used)
(not used)
4000
Blank Q Segment
8000
No Move
(not used)
* BLuAC drives only
NOTE: Items in
bold italic represent Drive Faults, which automatically disable the motor. Use the OF
command in a Q Program to branch on a Drive Fault.
NOTE: See Appendix for more detailed information on Alarm Codes.
Examples:
Command
Drive sends
Notes
AL
AL=0000
No alarms
AL
AL=0001
Position limit alarm
AL
AL=0201
Position limit and bad encoder signal alarms