1
1
motor stall (w/ optional encoder only)
1
2
move attempted while disabled
2
1
CCW limit
2
2
CW limit
3
1
over temp
3
2
excess regen
4
1
over voltage
4
2
under voltage
4
3
Bad Si program instruction
5
1
over current / short circuit
5
2
motor resistance out of range
6
1
open motor winding
6
2
bad encoder signal (w/ optional encoder only)
7
1
serial communication error
ST-Q/Si LED codes
Items in
bold italic are Drive Faults.
DESCRIPTION
-
solid
Motor disabled
-
flashing slowly
Motor enabled
-
flashing quickly Q program running (Q drives only)
1
1
motor stall (w/ optional encoder only)
1
2
move attempted while disabled
2
1
CCW limit
2
2
CW limit
3
1
over temp
3
2
internal voltage out of range
4
1
over voltage
4
2
under voltage
4
3
Bad Si program instruction
5
1
over current / short circuit
6
1
open motor winding
6
2
bad encoder signal (w/ optional encoder only)
7
1
serial communication error
ST-S LED codes
Items in
bold italic are Drive Faults.
DESCRIPTION
-
solid
Motor disabled
-
flashing slowly
Motor enabled