De - deceleration, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 62: Examples

62
920-0002 Rev. I
2/2013
Host Command Reference
DE - Deceleration
Compatibility: All drives
Affects:
FC, FD, FE, FL, FM, FO, FS, FP, FY, SH commands
See also:
AM, DE, DI, DC, VE commands
Sets or requests the deceleration rate used in point-to-point move commands in rev/sec/sec.
Command Details:
Structure
DE{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
“B” (018)
Note: The DE command uses different units than the “B”
register; see Data Registers section for details
Parameter Details:
Parameter #1
Deceleration rate
- units
rev/sec/sec (rps/s)
- range
0.167 to 5461.167 (resolution is 0.167 rps/s)
Examples:
Command
Drive sends
Notes
DE125
-
Set deceleration rate to 125 rev/sec/sec
DE DE=125