Examples – Applied Motion RS-232 User Manual
Page 69

69
920-0002 Rev. I
2/2013
Host Command Reference
Examples:
Command
Drive sends
Notes
EF1
-
Turn ON Stall Detection function
EF EF=1
EF6
-
Enable Stall Prevention with time-out
EF EF=6
Example encoder alignment sequence (STM24):
CC6
Raise current to 6A
CI5.4
Raise idle current to 5.4A*
EF1
Enable Stall Detection feature
CC3
Lower current to normal running level (application dependent)
CI2.4
Lower idle current to normal running level (application dependent)
If this is done through a Q program, add a short delay after raising current levels:
CC6
Raise current to 6A
CI5.4
Raise idle current to 5.4A*
WT1
Short delay
EF1
Enable Stall Detection feature
CC3
Lower current to normal running level (application dependent)
CI2.4
Lower idle current to normal running level (application dependent)
* 90% of CC; see CI command for details