Iv - immediate velocity, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 113: Examples

113
920-0002 Rev. I
2/2013
Host Command Reference
IV - Immediate Velocity
Compatibility: All drives
Requests present velocity of the motor in rpm. There are two different velocities that can be read back: the
motor’s actual velocity and the motor’s target velocity.
Command Details:
Structure
IV(Parameter #1)
Type
IMMEDIATE
Usage
READ ONLY
Non-Volatile
NO
Register Access
“v” (070) Actual velocity (servo drives and stepper drives
with encoder)
“w” (071) Target velocity
Parameter Details:
Parameter #1
Velocity selector
- units
integer
- range
0 = actual velocity request (servo drives and stepper drives
with encoder)
1 = target velocity request
Examples:
Command
Drive sends
Notes
IV0
IV=1000
Servo motor is running at 1000 rpm
IV1
IV=1000
Target motor velocity is 1000 rpm