R& - register and, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 192: Examples

192
920-0002 Rev. I
2/2013
Host Command Reference
R& - Register AND
Compatibility: Q drives only
Affects:
All data registers
See also:
R+, R-, R*, R/, RD, RI, QJ commands
Do a “bit-wise” AND of the contents of the first data register with the contents of the second data register and
place the result in the accumulator data register, User-Defined register “0”. This is a 32-bit operation. This
operation affects the “condition code” use by the QJ (Queue Jump) command.
All math operations affect the “condition code” used by the QJ (Queue Jump) command. Can set condition codes
T, F, N, P, and Z.
Command Details:
Structure
R&(Parameter #1)(Parameter #2)
Type
BUFFERED
Usage
WRITE ONLY
Non-Volatile
NO
Register Access
“0” (000), Accumulator
Parameter Details:
Parameter #1
First data register
- units
data register assignment
- range
All data registers
Parameter #2
Second data register
- units
data register assignment
- range
All data registers
Examples:
Command
Drive sends
Notes
R&s1
-
AND the contents of status register “s” and user-defined register “1”
and place the result in accumulator register “0”