Zc - regen resistor continuous wattage, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 223: Examples

223
920-0002 Rev. I
2/2013
Host Command Reference
ZC - Regen Resistor Continuous Wattage
Compatibility: BLuAC5 and STAC6 drives only
Sets or requests the regeneration resistor wattage value. BLuAC and STAC drives dynamically calculate the
continuous wattage induced into an external regeneration resistor and must know the continuous wattage rating of
the regen resistor to do this effectively.
Command Details:
Structure
ZC{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
Yes
Register Access
None
Parameter Details:
Parameter #1
Continuous wattage value of regen resistor
- units
Watts
- range
1 - 1000
Examples:
Command
Drive sends
Notes
ZC250
-
External regen resistor with value of 250 continuous watts is
connected to the drive
This manual is related to the following products: