VM - Maximum Velocity
Compatibility: Servo drives
Affects:
Analog Velocity mode
See Also:
AM, VC, VE commands
Sets or requests the maximum motor velocity in rev/sec. Used in analog velocity mode to limit the maximum
speed of the drive.
Command Details:
Structure
VM{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
None
Parameter Details:
BLu, SV
Parameter #1
Move velocity
- units
rev/sec (rps)
- range
0.0042 - 133.3333 (resolution is 0.0042 rev/sec)
Examples:
Command
Drive sends
Notes
VM50
-
Set maximum move velocity to 50 rev/sec
VM VM=50