Af - analog filter, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 22: Examples

22
920-0002 Rev. I
2/2013
Host Command Reference
AF - Analog Filter
Compatibility: All drives
Affects:
All commands using the analog inputs
See also:
IA, CM commands
Applies a digital filter to the analog input(s). This is a simple single pole filter that rolls off the analog input. The
filter value of the AF command is related to the desired value of the analog filter in Hz by the following equation:
Filter value = 72090 / [ (1400 / x ) + 2.2 ]
where x = desired value of the analog filter in Hz
Command Details:
Structure
AF{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
Setting the AF command will affect the responsiveness of
the “a”, “j”, and “k” registers to changes in analog voltage
Parameter Details:
Parameter #1
Filter value
- units
integer (see formula above)
- range
0 - 32767* (0 disables the filter)
* An AF value of 28271 equates to 4000.425 Hz. Setting the AF command to anything higher than 28271 has
a negligible effect on the analog filter. In other words, the maximum value of the filter is approximately 4000
Hz.
Examples:
Command
Drive sends
Notes
AF5000
-
Make the analog input bandwidth 114.585 Hz
AF AF=5000