Mr - microstep resolution, Command details, Parameter details – Applied Motion RS-232 User Manual
Page 141: Examples

141
920-0002 Rev. I
2/2013
Host Command Reference
MR - Microstep Resolution
Compatibility: All Stepper Drives
Affects:
Microstep Resolution
See also:
EG command
The MR command allows the user to set or request the Microstep Resolution of the drive.
NOTE: The MR command has been deprecated, and should no longer be used. It is included here solely for
compatibility with older programs. New applications should make use of the EG command.
Command Details:
Structure
MR{Parameter #1}
Type
BUFFERED
Usage
READ/WRITE
Non-Volatile
YES
Register Access
None
Parameter Details:
Parameter #1
Microstep Resolution (code)
- units
Integer
- range
0 - 15:
Code, steps/rev
0 = 200
1 = 400
3 = 2000
4 = 5000
5 = 10,000
6 = 12,800
7 = 18,000
8 = 20,000
9 = 21,600
10 = 25,000
11 = 25,400
12 = 25,600
13 = 36,000
14 = 50,000
15 = 50,800
Examples:
Command
Drive sends
Notes
MR8
-
Set the drive’s microstep resolution to 20,000 steps/rev
MR MR=8