beautypg.com

Presetting the master data (preset mode), Presetting the master data (preset mode) -35 – KEYENCE DV-90 User Manual

Page 95

background image

4-35

4

E DV-90-IM

Ba
si

c

Func

tions

4-7 2-Point Verification Function

5

Exit the setting mode.

Press the

key twice.

Setting of the 2-point verification function is completed

Presetting the Master Data (Preset Mode)

Two preset master data items (Master data 1 and 2) are required to preset a record number.

1

Press the

key.

The preset LED illuminates and the display moves
to the preset mode. The record number indictor
LED shows “001”. (EMPTY) is displayed on the
LCD, which indicates that Master data 1 (M1) is not
preset.

2

Read the first code (Master data 1) with the

code reader.
The buzzer sounds, and the read data is set as Mas-
ter data 1. The LCD displays the destination to
which Master data 2 (M2) is registered. The LED
still reads “001”.

3

Read the second code (Master data 2) with

the code reader.
The buzzer sounds, and the read data is set as Mas-
ter data 2.
The LED increments to “002” and the LCD displays
“M1:” for the new record. Continue steps 2 and 3
until all presets have been entered.

ESC

OK

NG

PRESET

12

11

10

9

8

7

6

5

4

TRG1

TRG2

3

2

1

ERR

( E M P T Y )

M 1 :

PRESET

( E M P T Y )

M 2 :

( E M P T Y )

M 1 :