2-Point Verification Function

This function is used to compare and verify two data items with a group of two master data in the order that the
data is read.
Verify OK is output if the two scans match an existing preset.

2-point Verification Function

The 2-point verification function compares the two read data items with the two master data items.
If data 123 and 456 are registered as master data, OK is output when the read data are 123 and 456
as well. NG is output when the data read does not match the master data.

In the 2-point verification function, Master data 1 and 2 are registered to a single preset. Verify OK
is determined when the two read data items match the registered data.
The operation flow for working with the 2-point verification function is as follows.

1 Selecting the 2-point verification function
2 Presetting the master data
3 Working with the 2-point verification function

Selecting the 2-point Verification Function

1

Move to the setting mode.

Press the

key for one second. The mode changes

to the setting mode.

2

Display the basic settings menu.

Place the cursor on “1 Main” by pressing the

or

key. Then press the

key.

3

Specify the verification type.

Display “Verify Type” by pressing the

or

key. Then press the

key.

4

Select the 2-point verification function.

Place the cursor on “2Points” by pressing the

or

key. Then press the

key.

Master data

First data reading

Second data reading

Verify

Verify

Master

data 1

Master

data 2

1 2 3

4 5 6

1 2 3

4 5 6

OK

M a i n

2

V e r i f y

1

MENU

0 1

V e r i f y T y p e

0 : N o r m a l

0 1

V e r i f y T y p e

0 : N o r m a l

0 1

V e r i f y T y p e

5 : 2 P o i n t s