1 code reader setup basics, Code reader setup basics -2, Code reader setup basics – KEYENCE DV-90 User Manual
Page 26
2-2
2
Initial Setup
of the Cod
e
Reade
r
E DV-90-IM
2-1
Code Reader Setup Basics
This section describes the preparation flow before using the DV-90.
1
In the settings of the DV-90, select "CR1 Type" in "Main".
Specify the type according to the code reader to connect.
(Setting procedure)
(1) Press the
key for one second to enter the setting mode.
(2) Select “1 Main” and press the
key.
(3) Press the
key twice to display “03 CR1 Type”.
(4) Press the
key to display a cursor.
(5) Select “TypeA,B,C,D,E, or Others”, and press the
key.
(6) Press the
key twice to exit the setting mode.
2
Configure the settings of the connecting code reader as follows.
If the code reader is at default, no setting change is required.
• Baud rate : 9600 bits/s
• Data length
: 7 bits
• Parity
: Even
• Stop bit length : 1 bit
• Header
: None
• Terminator
: CR or CR LF
• Communication protocol : No hand shaking
• Baud rate : 9600 bits/s
• Data length
: 8 bits
• Parity
: None
• Stop bit length : 1 bit
• Header
: None
• Terminator
: CR or CR LF
• Communication protocol : No hand shaking
• Baud rate : 115200 bits/s
• Data length
: 8 bits
• Parity
: Even
• Stop bit length : 1 bit
• Header
: None
• Terminator
: CR
• Communication protocol : No hand shaking
Code reader model name
Type
BL-1300/700/600/180 Series
Type A
HR-50RK/40RK/UC51
BL-N70RKE/N9R
Type B
TL-800, TL-70R
Type C
BL-210RK
Type D
SR Series, HR-100
Type E
Other code readers
Others
Reference
By specifying the code reader type, the settings such as the default values of the communi-
cation setting of the DV-90 and pin assignment of PORT1 are modified to suit the specified
code reader.
Note
•
If the setting cannot be changed on the code reader side, adjust the DV-90 settings for
“PORT1” in the setting mode of the DV-90. (
Refer to 6-8.)
•
If you are using the BL-1300/700/600/180 and the code reader setting cannot be checked, the
DV-90 can detect it automatically.
Refer to page 2-5 for automatic detection.
MENU
ESC