3 data write timing, Data write timing -17, Data write timing – KEYENCE DV-90 User Manual
Page 217
9-17
E DV-90-IM
9
PLC Link
9-3
Data Write Timing
Note that the following flowchart shows the writing of data to the PLC when viewed from the DV-90.
Operations such as “Read trigger control”, “Sequence processing”, “Active record number change”, and “Inter-
lock release” are not taken into consideration.
Normal verification/Active verification
The data to be written is as shown below.
“-” indicates that the data will not be overwritten. (The previous data is retained.)
at Verify OK
at Verify NG
at Read Error
X+18 Read Number
1
1
1
X+19 Verify Count
1 to 65535
1 to 65535
-
X+20 Record Number
1 to 900
999
997
X+21 Output Number
1 to 900
999
997
X+22 Read Quality Check
0 or 1
0 or 1
-
Y1 Data 1
Output data
Output data
ERROR
Y2 Data 2
-
-
-
Y3 Data 3
-
-
-
Yes
No
(Read Error)
Wait for the data from the code reader
Verify with the master table
Write “X+18 Read Number”
Write “X+20 Record Number”
Write “X+21 Output Number”
Write “Y1+00 … Data”
Write “X+09 Data Write Complete”
Write “X+19 Verify Count Value”
Write “X+22 Read Quality Check”
Read OK?
Verify mode starts