7 PLC Program Examples

Data read process

•When the “Write Complete Confirmation Flag” dis-

plays “1: Data Write Complete”, it starts processing
the written data. After the process is completed,
each flag is initialized.
* D10 is valid only in “Sequence processing”.

Select active record

Set the Active record number to 1 from Input X1.

Set the Active record number to 2 from Input X2.

Set the Active record number to 3 from Input X3.

MOV

K0

D9

LD=

D9

K1

MOV

K1

D10

MOVP

K0

D11

MOVP

K1

D12

MOVP

K0

D11

MOVP

K2

D12

MOVP

K0

D11

MOVP

K3

D12

This processes

data programs

written in DM

100 and later.

END