KEYENCE DV-90 User Manual
Page 198
8-20
E DV-90-IM
8
Ser
ia
l Comm
unicati
on
8-3 Command Communication Details
(Representation of data)
Underlined numbers are default values
(Command formats)
MGET [Verify Type]
[Record number]
• For “Verify Type” and “Record number”, refer to (Representation of data) shown above.
• The responses differ depending on the type of verification in use. The commands that follow the
“Output number” are sent (with
s), and are shown in the table “Command formats” of the
master table registration command, on the previous page.
Verify Type
0: Verify Normal 1: Verify Active 2: Verify Step
3: Verify 3points-A 4: Verify 3points-B 5: Verify 2points
Record number
001 through 900
Output number
001 through 900
Port number limitation
1: PORT1 2: PORT2 3: ALL
Reference data
Reference data string (16 characters maximum)
No data in default setting
Master data 1
Master data
Master data character string (500 characters maximum)
No data in default setting
Designation
0: NONE 1: Digit 2: Date Compare
Limit direction
1: Forward 2: Reverse
Limit start
001 through 500
Limit digits
001 through 500
Compare logic
0: = 1: < 2: > 3:
≤ 4: ≥
Master data 2
Master data
Master data character string (500 characters maximum)
No data in default setting
Designation
0: NONE 1: Digit 2: Date Compare
Limit direction
1: Forward 2: Reverse
Limit start
001 through 500
Limit digits
001 through 500
Compare logic
0: = 1: < 2: > 3:
≤ 4: ≥
Master data 3
Master data
Master data character string (500 characters maximum)
No data in default setting
Designation
0: NONE 1: Digit 2: Date Compare
Limit direction
1: Forward 2: Reverse
Limit start
001 through 500
Limit digits
001 through 500
Compare logic
0: = 1: < 2: > 3:
≤ 4: ≥
Master table confirmation
HT
HT