beautypg.com

KEYENCE DV-90 User Manual

Page 198

background image

8-20

E DV-90-IM

8

Ser

ia

l Comm

unicati

on

8-3 Command Communication Details

(Representation of data)

Underlined numbers are default values

(Command formats)

MGET [Verify Type]

[Record number]

• For “Verify Type” and “Record number”, refer to (Representation of data) shown above.

• The responses differ depending on the type of verification in use. The commands that follow the

“Output number” are sent (with

s), and are shown in the table “Command formats” of the

master table registration command, on the previous page.

Verify Type

0: Verify Normal 1: Verify Active 2: Verify Step

3: Verify 3points-A 4: Verify 3points-B 5: Verify 2points

Record number

001 through 900

Output number

001 through 900

Port number limitation

1: PORT1 2: PORT2 3: ALL

Reference data

Reference data string (16 characters maximum)

No data in default setting

Master data 1

Master data

Master data character string (500 characters maximum)

No data in default setting

Designation

0: NONE 1: Digit 2: Date Compare

Limit direction

1: Forward 2: Reverse

Limit start

001 through 500

Limit digits

001 through 500

Compare logic

0: = 1: < 2: > 3:

≤ 4: ≥

Master data 2

Master data

Master data character string (500 characters maximum)

No data in default setting

Designation

0: NONE 1: Digit 2: Date Compare

Limit direction

1: Forward 2: Reverse

Limit start

001 through 500

Limit digits

001 through 500

Compare logic

0: = 1: < 2: > 3:

≤ 4: ≥

Master data 3

Master data

Master data character string (500 characters maximum)

No data in default setting

Designation

0: NONE 1: Digit 2: Date Compare

Limit direction

1: Forward 2: Reverse

Limit start

001 through 500

Limit digits

001 through 500

Compare logic

0: = 1: < 2: > 3:

≤ 4: ≥

Master table confirmation

HT

HT