beautypg.com

KEYENCE DV-90 User Manual

Page 233

background image

9-33

9

E DV-90-IM

PLC Link

9-5 Settings

„ CJ Series, CS1 Series (CPU internal port)

CS1W-SCB21/41 (communication board),

CS1W-SCU21 (communication unit)
(DIP switch)

(PC system setting)

m = D30000 + 100 x unit number

* In the initial setting, the baud rate is set to 9600 bits/s, data length to 7, parity to even, and stop bit

length to 2. When you want to change the settings, set the bit to “1”, and configure the desired
settings in the above locations.

SW number

Setting value

Setting content

5 OFF

Cancels the fixed settings of the communication port/communication condition

CPU internal

RS-232C port

Communication

board

Communication unit

Bit

Setting item

DM value

160 channels

PORT1: DM32000
PORT2: DM32010

PORT1: m
PORT2: m+10

00 to 01

Parity
00: Even

0000

2

Stop bit
0: 2 bits

3

Data length
0: 7 bits

8 to 11

Communication mode
00: Upper link

15

Desired setting
0: Default value *

161
channels

PORT1: DM32001
PORT2: DM32011

PORT1: m
PORT2: m+10

00 to 07

Communication speed
06: 9600 bits/s

0006